Mailing List ecs-isp@2rosenthals.com Archived Message #475

From: "Steven Levine" <ecs-isp@2rosenthals.com> Full Headers
Undecoded message
Subject: Re: [eCS-ISP] InJoy FW 4.2.2 issue with a rule "failed to send packet"
Date: Sat, 13 May 2023 20:38:22 -0700
To: "eCS ISP Mailing List" <ecs-isp@2rosenthals.com>

In <list-7151547@2rosenthals.com>, on 05/13/23
   at 10:17 PM, "Massimo S." <ecs-isp@2rosenthals.com> said:

HI Massimo,

>BWW asked to use a lower port for the rule, i tried, but it show the same
>issue

I would have been surprised if it did.

FWIW, you don't really yet know exactly what it triggering the failure.

To track this down, you need start with a working setup and add rules one
by one until you get the failure.  Once you get to this point, swap the
last rule added with the rule you would have added it the failure had not
occurred.

If the failure presists, you know the number of rules is contributing to
the failure in some way.  If not you know that something about the
combined set of rules is triggering the problem.

You know you can do a lot of testing without touching your working
production rule set.  Copy your injoy install to a test directory.  Then
when you have some time to test, shutdown the production gateway and run
the gateway from he test directory.

Steven

--
----------------------------------------------------------------------
"Steven Levine" <steve53@earthlink.net>  Warp/DIY/BlueLion etc.
www.scoug.com www.arcanoae.com www.warpcave.com
----------------------------------------------------------------------


Subscribe: Feed, Digest, Index.
Unsubscribe
Mail to ListMaster