List ecs-isp@2rosenthals.com Arkiverade meddelande #733

Från: "Massimo S." <ecs-isp@2rosenthals.com> Meddelandehuvud
Oavkodat meddelande
Ämne: Re: [eCS-ISP] Bind 9.11.37 issue - ticket #784 - update
Datum: Fri, 17 May 2024 20:28:46 +0200
Till: eCS ISP Mailing List <ecs-isp@2rosenthals.com>

i now have set it to 30

thanks

massimo

Il 16/05/2024 17:19, Lewis G Rosenthal ha scritto:
On 05/16/24 11:04 am, Massimo S. wrote:
Hi all,

my own "startup.cmd" do:

inetcfg -s keepalive 60
inetcfg -set all

i've now seen with inetcfg -get all that my keepalive is still the very old default: 300


You just overwrote your 60 second keepalive (likely still too long, anyway) with whatever was written in %ETC%\inetcfg.ini (default=300 seconds).

Just:

inetcfg -s keepalive 15
inetcfg -g all

*once*

Remove any inetcfg references in STARTUP.CMD. When the stack initializes, it will automatically read %ETC%\inetcfg.ini which will have keepalive 30 in it.

maybe this could cause issues on the stack ip


Ya think?

A 5 minute keepalive on a modern LAN or even broadband connection is almost forever.

i don't understand why inetcfg -s keepalive 60 at startup don't work
anyway i've set it manually in the "lunch break" and rebooted the VM


It doesn't work because inetcfg.ini is higher and you are reading that (inetcfg -get all = read all settings from %ETC%\inetcfg.ini and overwrite what is currently in use).

<snip>


Prenumerera: Sändning, Uppsamling, Index.
Stoppa prenumeration
Meddelande till ListMaster