On Sun, 25 Feb 2007 18:52:16 +0100 (CET), Jan van Wijk wrote:
>Hi Eric,
>
>On Sun, 25 Feb 2007 11:33:51 -0600 (CST), Eric A. Erickson wrote:
>
>>I had to rebuild my T43 and now after installing eCS Beta 3 I get the
>>following error during boot.
>>
>>No valid hardware info in protocol.ini for ("WRNDS32$ ")
>
>Known problem, I had the same, you are most likely missing
>the VENDOR and DEVICE lines missing, see below for what
>it should look like (Intel 2200 on a T42p)
>
>
>++++
>[W8086X4220_NIF]
>
> DriverName = WRND32$
> VENDOR = 0x8086
> DEVICE = 0x4220
> NDIS_SYS = "W29N50.SYS"
> NDIS_INF = "w8086x4220.inf"
> SSID = "w34rfvbhu89ol"
> DEBUGLEVEL = "NONE"
> OPTIONS = "NONE"
>++++
>
>
>Regards, JvW
>
>
Jens,
Actually it turned out to be something totally different. I did not
have the Wired (Broadcom) NIC defined in MPTS yet. When I added the
IBM TP43 Broadcom NIC Driver, it now loads.
My next problem is that xWLan 3.0 does not show the device as
available. When I click on the device tab nothing is shown. There are
no strange error messages in the LanTran.log and I'm still running
the 1.24 Bios on my TP 43.
I had this working once, before the re-build, but I'm clueless at the
moment as to what to try next.
Eric Erickson
Elvish Software Foundry, Inc. - Internet: drowelf@vnet.net
Already where I want to be Today - Voice/Fax: (218)-398-2625